General specifications | |
---|---|
Detection type | magnetic sampling |
Device type | Multiturn absolute encoder |
Measurement range | min. 0 ... 22.5 ° max. 16 x 360 ° |
Resolution | 16 Bit (12 bits/revolution) |
Functional safety related parameters | |
MTTFd | 566 a at 40 °C |
Mission Time (TM) | 20 a |
Electrical specifications | |
Operating voltage | 15 ... 30 V DC , PELV |
Current consumption | typ. 40 mA |
Input 1 | |
Input type | lower limit of measurement range (Set 1) |
Signal voltage | |
Signal duration | min. 1 s |
Input 2 | |
Input type | upper limit of measurement range (Set 2) |
Signal voltage | |
Signal duration | min. 1 s |
Analog output | |
Output type | 1 analog output, current |
Default setting | rising ramp at ccw rotation |
Linearity error | ? 0.15 % |
Load resistor | max. 500 ? ; Max. value for operating voltage 15 V. For higher operating voltage higher load resistance can be used. |
Connection | |
Terminal compartment | see ordering information |
Standard conformity | |
Degree of protection | DINEN60529, IP66 |
Climatic testing | DINEN60068-2-3, no moisture condensation |
Emitted interference | EN61000-6-4:2007 |
Noise immunity | EN61000-6-2:2005 |
Shock resistance | DINEN60068-2-27, 100g, 6ms |
Vibration resistance | DINEN60068-2-6, 10g, 10...1000Hz |
Ambient conditions | |
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Material | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) |
Rotational speed | max. 3000 min -1 |
Moment of inertia | 180 gcm2 |
Starting torque | ? 4 Ncm |
Shaft load | |
Data for application in connection with hazardous areas | |
EU-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X |
Directive conformity |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000< |